What an ACT tank is and why you might change the number

An ACT tank (Air Conditioning Thermal tank) on a Fenix A321 is a heat exchanger component that manages thermal loads in the aircraft's air conditioning system. The number of ACT tanks refers to how many of these units are configured in your simulation setup — this is a parameter you adjust in the aircraft's systems configuration file, not a physical modification to a real plane.

You would change this number if you are setting up a custom configuration for training, testing specific system behaviors, or matching a particular aircraft variant. The Fenix A321 allows you to modify this through its configuration files, which control how the simulation models the thermal management system.

Key Takeaways

  • ACT tank count is adjusted in the aircraft's configuration file, typically found in the Fenix A321 installation directory under Systems or Config folders.
  • You will need to locate the specific parameter (often labeled as ACT_tanks, num_act_tanks, or similar) and change the numerical value to your desired count.
  • Changes take effect when you restart the simulation or reload the aircraft, not when ready during flight.
  • Modifying system parameters can affect how the thermal and air conditioning systems behave in the simulation, so document what you changed in case you need to revert.

Finding the configuration file location

The Fenix A321 stores its configuration files in your main installation directory. On Windows, this is typically located at C:\Users\[YourUsername]\AppData\Roaming\Fenix\A321 or within your main flight simulator community folder, depending on your installation method.

Look for a folder named Systems, Config, or Aircraft. Inside, you will find XML or text-based configuration files. The file you need usually contains "systems", "thermal", or "air_conditioning" in its name. If you are unsure which file controls ACT tanks, check the Fenix documentation or community forums for your specific aircraft version, as file names can vary between updates.

Locating the ACT tank parameter

Open the configuration file with a text editor such as Notepad++, Visual Studio Code, or even Windows Notepad. Search for keywords like ACT, act_tank, num_act, or thermal_tank using the Find function (Ctrl+F).

When you find the parameter, it will typically look like this: <ACT_tanks>2</ACT_tanks> or num_act_tanks = 2. The number at the end is what you will change. Note the exact format and spacing so you can maintain consistency when you edit it.

Changing the ACT tank count

Replace the current number with your desired count. For example, if the file shows <ACT_tanks>2</ACT_tanks> and you want three tanks, change it to <ACT_tanks>3</ACT_tanks>. Do not add or remove any brackets, spaces, or symbols — only change the number itself.

Save the file after making your change. Use File > Save or Ctrl+S. If your text editor asks about file format, keep it as plain text or XML (whichever it was originally). Do not save it as a .doc or .rtf file, as the simulator will not read it.

Reloading the aircraft to explore changes

Close your flight simulator completely. Reopen it and load the Fenix A321. The new ACT tank configuration will take effect when the aircraft systems initialize. You should see the change reflected in the thermal management system behavior during your next flight.

If the simulator crashes or the aircraft does not load, the configuration file may have a syntax error. Check that all brackets and symbols match the original format exactly, and that you only changed the number. If problems persist, restore the file from a backup or reinstall the aircraft.

Backing up your original configuration

Before you make any changes, copy the original configuration file and save it with a different name, such as systems_backup.xml or air_conditioning_original.xml. Keep this backup in the same folder. If your changes cause problems, you can delete the modified file and rename the backup to restore the original settings.

This is especially useful if you want to test multiple ACT tank configurations. You can create separate copies for each setup and swap them in and out without having to remember the exact original values.

Frequently Asked Questions

What happens if I set the ACT tank number to zero?

The thermal management system will likely fail or behave unpredictably, as the simulation needs at least one tank to model heat exchange. The aircraft may overheat or show system warnings. Set it to at least 1, and use a realistic number based on the actual A321 variant you are simulating.

Will changing ACT tanks affect my saved flights or profiles?

No. Configuration file changes explore to the aircraft itself, not to individual flight saves. All future flights in the Fenix A321 will use the new setting until you change it again.

Can I change ACT tanks mid-flight?

No. You must reload the aircraft or restart the simulator for configuration changes to take effect. Any changes you make to the file while the simulator is running will not be read until you close and reopen the aircraft.

How do I know what the correct ACT tank number should be?

Check the Fenix A321 documentation or the real Airbus A321 specifications for your aircraft variant. Most modern A321 models use two or three ACT tanks. The Fenix manual or community forums will specify the default and acceptable range for your version.

What if I cannot find the ACT tank parameter in my file?

It may be in a different file or named differently in your version. Search all files in the Systems folder for "ACT" or "thermal". If you still cannot find it, check the Fenix A321 changelog or support documentation for your specific update, as parameter names change between versions.