What an RV generator does and why it matters
An RV generator is a portable power plant that produces electricity when your vehicle is parked and the engine is off. It runs on gasoline, diesel, or propane and powers your lights, refrigerator, air conditioning, water heater, and other appliances while you're camping or stationary. Without one, you're limited to whatever battery power your RV's house battery can hold—typically a few hours of basic lighting and maybe a few minutes of air conditioning before the battery drains completely.
The generator sits in a compartment at the back or side of your RV, usually under a metal cover. When you turn it on, it produces alternating current (AC) electricity at 120 volts, the same voltage your home uses. This is different from your RV's 12-volt house battery system, which powers only the lights and water pump. The generator is what lets you run real appliances—the air conditioner, microwave, and electric heater—things that draw far more power than a battery can supply.
Whether you need a generator depends on how you camp. If you stay at RV parks with full hookups (where you plug into shore power), you don't need a generator at all. If you boondock or dry camp—park without hookups—a generator becomes essential for comfort and safety, especially in hot or cold weather.
Key Takeaways
- RV generators produce 120-volt AC power to run appliances when you're parked away from hookups, while your house battery provides only 12-volt DC power for lights and water pumps.
- Generator size matters: a 2,000-watt unit handles basic loads like lights and a microwave, but running air conditioning or an electric heater requires 5,000 to 7,000 watts or more.
- Gasoline generators are cheaper upfront but noisier and less fuel-efficient; diesel and propane units cost more but run quieter and longer between refueling.
- Regular maintenance—oil changes, fuel stabilizer, and load testing—prevents starting failures and extends the life of a generator that may sit unused for months.
- Inverter generators produce cleaner power safer for electronics and are quieter than conventional models, but cost significantly more.
Generator size: matching power output to what you actually run
Generator size is measured in watts, and choosing the right one is about knowing what you want to power at the same time. A 2,000-watt generator can run your lights, refrigerator, and microwave, but not the air conditioner. A 5,000-watt unit handles air conditioning plus other appliances. A 7,000-watt or larger generator can run almost anything in your RV simultaneously, including an electric heater.
The confusion happens because appliances have two power ratings: running watts and starting watts. The air conditioner might draw 3,500 running watts but need 5,000 watts for the first second when the compressor kicks on. If your generator can't deliver that starting surge, it will shut down or the air conditioner won't start. Check your RV's manual or the nameplate on each appliance to see the starting watts, then add them up for everything you might run together.
Larger generators are heavier, use more fuel, and take up more space. Smaller ones are cheaper and quieter but limit what you can do. Most RV owners with air conditioning choose 5,000 to 7,000 watts as a practical middle ground. If you boondock in cold weather and want electric heat, you'll need 7,000 watts minimum.
Fuel type: gasoline, diesel, and propane trade-offs
Most RV generators run on gasoline because it's cheap and available everywhere. Gasoline generators are also the least expensive to buy. The downside is noise—a typical gasoline generator produces 75 to 85 decibels, loud enough that neighbors at a campground will hear it. Gasoline also degrades in the tank if the generator sits unused for months, which is common in RVs. Stale fuel clogs the carburetor and prevents starting.
Diesel generators are more efficient, quieter (around 70 decibels), and run longer on a tank of fuel. They cost more upfront and are heavier, but if you use your RV frequently or boondock for long stretches, the fuel savings add up. Diesel fuel is more stable than gasoline and won't gum up the carburetor as easily during storage.
Propane generators are quieter than gasoline and propane doesn't degrade in storage, so they start reliably after months of sitting. Many RVs already carry propane for the water heater and stove, so you can use the same tank. The trade-off is that propane generators produce less power per unit size and are harder to find for purchase. Some RV owners choose a small propane generator as a backup to their main gasoline unit.
Inverter generators versus conventional models
An inverter generator produces power differently than a conventional generator. It creates high-frequency AC power and then converts it to DC and back to AC, which results in a steady, clean electrical output. Conventional generators produce raw AC power that fluctuates slightly in voltage and frequency.
The practical difference: inverter generators are safe for sensitive electronics like laptops, phones, and modern RV appliances with computer controls. Conventional generators can damage these devices over time because the voltage spikes stress the components. Inverter generators also run quieter—often 10 to 15 decibels quieter—because they adjust engine speed to match the load instead of running at full throttle constantly.
The cost is significant. An inverter generator of the same wattage costs 50 to 100 percent more than a conventional model. For a 5,000-watt unit, you might pay $2,000 to $3,000 for an inverter model versus $1,000 to $1,500 for conventional. If you boondock frequently or camp near others, the quieter operation and electronics protection justify the expense. If you stay mostly at hookup parks, it's not necessary.
Starting and running your generator safely
Before you start a generator that's been sitting, check the oil level. Generators have a low-oil shutoff switch that prevents the engine from running if oil is too low, which protects the engine but also means it won't start if you've neglected maintenance. Fill it to the line on the dipstick, using the oil weight specified in your owner's manual—usually 10W-30 or 10W-40.
Turn the fuel valve to the on position (if your generator has one), set the choke to cold start, and pull the recoil starter or press the electric start button. Let it warm up for a minute before you load it with appliances. Never run a generator indoors or in an enclosed space—generators produce carbon monoxide, a colorless, odorless gas that kills. Run it outside, at least 20 feet from windows and doors.
Turn on appliances one at a time rather than all at once. This prevents the starting surge from overloading the generator. If the generator shuts down under load, you've exceeded its capacity—turn off an appliance and try again. Most RV generators have a circuit breaker that trips if you overload them; reset it by flipping the switch back on after you've reduced the load.
Maintenance that prevents starting failures
The most common generator problem is failure to start after sitting unused for weeks or months. This happens because gasoline oxidizes and leaves varnish in the carburetor. The fix is prevention: add fuel stabilizer to the tank before you store the RV. Fuel stabilizer keeps gasoline fresh for six months or longer. Pour it in according to the bottle's instructions, run the generator for 10 to 15 minutes to circulate the treated fuel through the system, then shut it down.
Change the oil every 50 to 100 hours of running time, or at least once a year if you run it less frequently. Old oil thickens and doesn't protect the engine. Check the air filter every season and replace it if it's clogged with dust. A dirty air filter makes the engine run rich (too much fuel, not enough air), which wastes fuel and fouls the spark plug.
If your generator won't start after storage, try these steps in order: drain the old fuel and replace it with fresh fuel plus stabilizer, clean or replace the spark plug, and check that the fuel valve is open and the choke is set correctly. If it still won't start, the carburetor likely needs cleaning by a small-engine mechanic. This is cheaper than replacing the generator and worth doing if the unit is otherwise in good condition.
Load testing and knowing your generator's real output
A generator's nameplate says it produces, for example, 5,000 watts. That's the maximum continuous output under ideal conditions. In reality, altitude, temperature, and age reduce that output. At high elevation, a generator produces 3 to 5 percent less power. In cold weather, it produces less power until it warms up. An older generator with worn internal parts produces less than a new one.
You can estimate your actual available power by running your largest appliance—usually the air conditioner—and watching the generator's load meter if it has one. If the meter shows 80 percent load when the air conditioner is running alone, you have little headroom for other appliances. If it shows 50 percent, you can safely add lights and a microwave without overloading.
If your generator doesn't have a load meter, you can use a portable power meter (available at hardware stores for $20 to $40) plugged into an outlet powered by the generator. Run the air conditioner and note the watts drawn. This tells you how much capacity remains for other appliances and helps you avoid overloading.
When to replace versus repair a generator
A generator that won't start after you've cleaned the carburetor and replaced the spark plug likely has internal engine damage or a failed alternator. Repair costs vary widely depending on the problem and the shop, but rebuilding a small engine typically runs $300 to $800. A new generator of the same size costs $800 to $2,000 depending on type and fuel.
If your generator is more than 10 years old and the repair costs more than half the price of a new unit, replacement usually makes sense. Older generators are less efficient, use more fuel, and are more likely to fail again. If it's newer and the repair is straightforward—a new carburetor or alternator—repair is usually the better choice.
Keep your receipt and warranty documentation. Most RV generators come with a one- to three-year warranty covering defects in materials and workmanship. If your generator fails within the warranty period, contact the manufacturer or the dealer where you bought it. Many will repair or replace it at no cost.
Frequently Asked Questions
Can I run my RV air conditioner on a small generator?
Only if the generator is 5,000 watts or larger. Most RV air conditioners draw 3,500 running watts and need 5,000 starting watts. A 2,000 or 3,000-watt generator will shut down when the compressor kicks on. Check your air conditioner's nameplate for the exact starting watts before you buy a generator.
How long can I run a generator continuously?
Most RV generators are designed to run 8 to 12 hours continuously at half load before needing an oil change. At full load, they may overheat and shut down after 4 to 6 hours. Check your owner's manual for the recommended duty cycle. Never run a generator longer than the manual allows without stopping to let it cool.
What happens if I overload my generator?
The circuit breaker trips and the generator shuts down to protect the engine from damage. Turn off an appliance, wait 30 seconds, and reset the breaker by flipping the switch. If the breaker trips repeatedly, you're trying to run more than the generator can handle—you need a larger unit or must choose which appliances to run together.
Is it safe to run a generator while driving the RV?
Yes, many RVs have generators designed to run while the vehicle is moving. The generator draws fuel from the RV's main tank and shuts off automatically if the tank gets too low. Check your owner's manual to confirm your generator is rated for mobile operation. Never run it in an enclosed space like a garage or storage unit.
Why won't my generator start after winter storage?
Stale gasoline has clogged the carburetor. Drain the old fuel, add fresh fuel with stabilizer, and try starting again. If it still won't start, remove and clean the spark plug, check that the choke is set to cold start, and try again. If the engine turns over but won't fire, the carburetor needs professional cleaning.